CONNECTING TO A TURNTABLE
Balanced inputs are provided for con-
necting up to two turntables to the 1008.
To avoid hum pickup in the cabling, it is
important to follow these instructions.
Do not connect pin 1 (chassis/
ground) to either pin 2 or 3 at any point
in the cable, turntable chassis, or tone-
arm. Pins 2 and 3 must only connect
directly to the cartridge pins. This can be
accomplished by several wiring schemes
shown on the next page.
Do not use the Boulder ABL2 input
adapter or other “standard” RCA Phono
to XLR adapter because they connect pin
1 to pin 3. These are intended only for line level use.
Use either a connection from pin 1 to the turntable chassis or a wire
from the CHASSIS screw terminal to the turntable chassis. Using both
might form a ground loop which will create hum.
One pair of Boulder PHRCA Adapters are provided. These will
convert 1008 inputs to RCA and give acceptable performance. A sepa-
rate ground wire is provided. However, obtaining a dedicated cable
with a connector specifically for your tonearm and with 3-pin connec-
tors is preferred.