EQUALIZATION
The Boulder 1008 Phono Preamplifier provides the standard RIAA
record equalization curve, along with the EMI, Columbia, and FFRR
curves. See the Equalization section for more details.
Select the RIAA equalization curve by pressing the pushbutton
labeled RIAA. All three remaining curves may be selected by using
the pushbutton labeled ALT EQ. Various alternate EQs are selected by
repeatedly pushing “ALT EQ” until the desired LED is red. The 1008
will immediately mute the outputs and the MUTE light will be red for
3 seconds. After that time, the output will be unmuted and the MUTE
indicator will be off.
Anytime a different equalization is selected, the 1008 will similarly
mute for 3 seconds.
If the chosen equalization curve is RIAA, the RIAA indicator will
be amber. If the chosen equalization curve is any other EQ curve, its
respective indicator will be red.